No longer available
Alternatives displayed on the right
Orcon HRC 500 EcoMax MVHR unit - 500 m³/h
500 m³ /h | Protective euro plug
{{ description }}
You save {{ discount.percentage }}%
{{ this.lastAddedShoppingCartItem.productable ? this.lastAddedShoppingCartItem.productable.displayName : '' }}
{{ lastAddedShoppingCartItem.productable.brand.display_name }}
Art. nr.: {{ lastAddedShoppingCartItem.productable.sku }}
{{ description }}
- Contributes to a healthy indoor climate
- Prevents moisture and mould problems
Description
The HRC 500 EcoMax is a quiet and energy-efficient MVHR unit from Orcon. The unit is suitable for all applications in residential construction and discharges as much clean filtered outdoor air as polluted indoor air. This recovers the heat from the exhausted polluted indoor air and transfers it back to the supplied filtered outdoor air. The Orcon HRC 500 has a capacity of 500 m³ /h.
Thanks to intelligent operation, the Orcon HRC 500 EcoMax ventilates only if it is necessary. The result: a healthy and comfortable indoor climate as well as lower energy bills.
Please note: the product will be delivered on a pallet .
Extended warranty: on this Duco product, beyond the usual 2-year warranty, you will receive 1 year additional warranty after registration.
Specifications
Intovent article number | ITV050106 |
Manufacturer item number | 22000100 |
Brand | Orcon |
Housing material | Plastic |
Suitable for wall mounting | Yes |
Suitable for floor mounting | Yes |
With thermal overload protection | Yes |
With digital display | Yes |
Suitable for wireless remote control | Yes |
Suitable for central heating boiler connection | No |
With bypass | Yes |
Residential connection, underside | No |
Residential connection, left side | Yes |
Residential connection, right side | Yes |
Residential connection, top | Yes |
Roof connection, side | Yes |
Roof connection, top | Yes |
Height (mm) | 888 |
Width (mm) | 760 |
Depth (mm) | 600 |
Type of speed control | Other |
Intovent recommends | No |
Nominal duct diameter (mm) | 180 |
Heat recovery by | Cross-counter-flow unit |
Housing material quality | Expanded polypropylene (EPP) |
Material heat exchanger | Plastic |
Suitable for ceiling mounting | No |
Left/right orientation reversible | Yes |
Max. air volume at 50 Pa (m³/h) | 500 |
Max. air volume at 100 Pa (m³/h) | 500 |
Max. air volume at 150 Pa (m³/h) | 500 |
Max. air volume at 200 Pa (m³/h) | 500 |
Max. air volume at 250 Pa (m³/h) | 500 |
Max. air volume at 300 Pa (m³/h) | 500 |
Power consumption at max. air volume at 100 Pa (kW) | 0.185 |
Thermal efficiency at 70 % air volume at 50 Pa (%) | 90.8 |
Type of motor | Electronically commutated (EC) |
Degree of protection (IP) | IP31 |
Voltage (V) | 230 |
Frequency (Hz) | 50 |
Number of phases | 1 |
Fuse size of the device (A) | 6 |
Electrical connection | Connecting cord with plug with protective contact |
Energy efficiency class (1253/2014/EU) | A |
With digital display | No |
Supporting protocol for Modbus | Yes |
With wired control unit | No |
Suitable for wired control unit | No |
With zone controller | No |
Suitable for zone controller | Yes |
With heating element | No |
With volatile organic compound (VOC) sensor | No |
Suitable for extra VOC sensor | No |
With internal humidity (RH) sensor | Yes |
Suitable for (extra) humidity (RH) sensor | No |
With internal carbon dioxide (CO2) sensor | No |
Suitable for (extra) carbon dioxide (CO2) sensor | Yes |
With constant pressure control | No |
With constant volume flow control | Yes |
Type of frost protection | Other |
Connections outdoor air side | Insert end |
Connections residential side | Insert end |
Supply filter according to ISO 16890-1:2016 | ISO Coarse |
Efficiency supply filter according to ISO 16890-1:2016 (%) | 65 |
Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
Efficiency exhaust filter according to ISO 16890-1:2016 (%) | 65 |
Weight (kg) | 33.1 |
GTIN | 08718403863314 |
Electrical connection | Connecting cable with plug with protective contact |
Energy efficiency class according to 1253/2014/EU | A |
Electrical connection | Connecting cable with plug w/protective contact |
Power consumption at max. air volume at 100 Pa (W) | 0.185 |
Max. air volume at 50 Pa (Cubic metre per hour) | 500 |
Max. air volume at 100 Pa (Cubic metre per hour) | 500 |
Max. air volume at 150 Pa (Cubic metre per hour) | 500 |
Max. air volume at 200 Pa (Cubic metre per hour) | 500 |
Max. air volume at 250 Pa (Cubic metre per hour) | 500 |
Max. air volume at 300 Pa (Cubic metre per hour) | 500 |
Power consumption at max. air volume at 100 Pa (Watt) | 0.185 |
Thermal efficiency at 70 % air volume at 50 Pa (Percentage) | 90.8 |
Voltage (Volt) | 230 |
Frequency (Hertz) | 50 |
Fuse size of the device (Ampere) | 6 |
Nominal duct diameter (Millimetre) | 180 |
Efficiency supply filter according to ISO 16890-1:2016 (Percentage) | 65 |
Efficiency exhaust filter according to ISO 16890-1:2016 (Percentage) | 65 |
Height (Millimetre) | 888 |
Width (Millimetre) | 760 |
Depth (Millimetre) | 600 |